Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.115
Filtrar
1.
Oper Dent ; 48(4): 364-372, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37226698

RESUMO

OBJECTIVES: To compare the clinical performance of mildly acidic universal adhesives Scotchbond Universal (SU, 3M Oral Care, St Paul, MN, USA) and Prime & Bond Elect (PBE, Dentsply Sirona, Charlotte, NC, USA) in the restoration of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS: A total of 63 patients in need of 203 NCCL restorations participated in this randomized controlled clinical trial. Notch-shaped lesions were restored with Kalore (GC Corporation, Tokyo, Japan) after application of either SU or PBE, following the etch-and-rinse (ER) or self-etch (SE) techniques. Subjects were followed up for 60 months. The focus of the statistical analyses was on the change of outcome over time as assessed by the Modified USPHS rating system (ie, Alfa vs Bravo + Charlie outcomes). Logistic regression was performed for each outcome separately with compound symmetric variance-covariance structure assumed to consider a correlation of restorations within subjects. All analyses were conducted using SAS 9.4 (SAS, Cary, NC, USA). RESULTS: One-hundred twenty-nine teeth in 35 subjects were assessed at the 60-month follow-up. In addition, three restorations that failed prior to the 60-month evaluation, two of which were in subjects who did not present for the 60-month follow-up, were included in the statistical analysis. In total, two restorations in the SU_ER group and three restorations in the PBE_SE group failed the retention category. Statistically significant differences were obtained for the comparison of restorations in the PBE_SE and PBE_ER groups, where the former was 58% less likely to maintain a score of Alfa for marginal discoloration than the latter. CONCLUSIONS: SU and PBE demonstrated acceptable clinical performance at 60 months with regard to restoration retention. Phosphoric-acid etching of the NCCLs prior to adhesive application significantly improved the performance of PBE in regard to marginal discoloration.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Adesivos Dentinários/química , Resinas Compostas/química , Corrosão Dentária/métodos , Restauração Dentária Permanente/métodos , Adaptação Marginal Dentária , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Colo do Dente , Adesivos
2.
J Prosthodont Res ; 67(1): 35-44, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35691823

RESUMO

PURPOSE: The efficacy of etch-and-rinse, selective enamel-etching, and self-etching protocols for universal adhesives in follow-ups of over 12 months was compared in a network meta-analysis. STUDY SELECTION: Randomized controlled trials (RCTs) published from 1998 to 2022 that compared marginal staining, marginal adaptation, retention and fractures, post-operative sensitivity, or recurrence of caries that took place over 12-months post-restoration were selected. A network meta-analysis determined the performance of each adhesive protocol. RESULTS: After screening 981 articles, 16 RCTs were subjected to data extraction. Of which, 674 patients with 2816 restorations, were included in the network meta-analysis. The pooled risk of marginal discoloration following self-etching was significantly higher than that following etch-and-rinse at over 12, 24, and 36 months, which was time-dependent. The pooled risks of unfavorable marginal adaptation and unfavorable retention and fractures following self-etching were also significantly higher than that following etch-and-rinse, with the rates of unfavorable retention and fractures in non-carious cervical lesions increasing in a time-dependent manner. The pooled risks of marginal discoloration, unfavorable marginal adaptation, retention and fractures were similar between etch-and-rinse and selective enamel-etching protocols. Post-operative hypersensitivity and recurrence of caries were not significantly different among etch-and-rinse, selective enamel-etching, and self-etching protocols. CONCLUSIONS: In follow-ups over 12 months, esthetic and functional outcomes of restorations completed with an etch-and-rinse adhesive protocol were superior to the ones achieved with a self-etching strategy without selective enamel-etching. Selective enamel etching is recommended for self-etching systems. Biological responses were similar for all three adhesive strategies.


Assuntos
Adesivos , Restauração Dentária Permanente , Retenção de Dentadura , Humanos , Cárie Dentária/epidemiologia , Adaptação Marginal Dentária , Restauração Dentária Permanente/efeitos adversos , Restauração Dentária Permanente/métodos , Seguimentos , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Método Duplo-Cego , Corrosão Dentária/métodos
3.
Int Orthod ; 20(2): 100640, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35654673

RESUMO

OBJECTIVES: Orthodontic brackets are increasingly bonded to the surface of zirconium crowns due to the growing aesthetic demands in adults' restorations. Therefore, providing a reliable bond between these substrates is of great importance. This study aimed at investigating the shear bond strength (SBS) of orthodontic metal brackets bonded to zirconium treated by sandblasting. In addition, the value was compared with SBS between metal brackets and enamel. MATERIALS AND METHODS: Samples were divided into three groups including first premolar enamel specimens (n=20), untreated zirconium blocks (n=20) and sandblasted zirconium blocks (n=20). Enamel specimens underwent etching and bonding procedures using 37% phosphoric acid and 3M™ Scotchbond™ Universal adhesive. Zirconium blocks were randomly allocated to two groups. The first group was prepared by sandblasting with 50µm aluminium oxide particles (Al2O3) under 4 bars pressure followed by bonding brackets with 3M™ Scotchbond™ Universal adhesive. Metal brackets were also bonded to the untreated zirconium group using the same adhesive. All samples underwent thermocycling, and SBS was calculated using a universal testing machine with a crosshead speed of 1mm/min. Data were analysed using One-way Anova and Tukey's tests. RESULTS: The highest SBS was recorded in sandblasted zirconium group (26.17±8.22MPa) followed by enamel group (23.667±7.00MPa) and untreated zirconium group (11.49±7.00MPa). There was a significant difference between the SBS of untreated zirconium and that of two other groups. CONCLUSION: Perfect SBS was achieved by sandblasting pre-treatment, comparable to that of enamel. Therefore, sandblasting of zirconium crowns is recommended prior to bonding orthodontic brackets.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Condicionamento Ácido do Dente/métodos , Adulto , Coroas , Colagem Dentária/métodos , Cimentos Dentários , Esmalte Dentário , Corrosão Dentária/métodos , Análise do Estresse Dentário , Estética Dentária , Humanos , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Zircônio
4.
J Appl Oral Sci ; 28: e20190499, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32348441

RESUMO

Enzymatic degradation of the hybrid layer can be accelerated by the activation of dentin metalloproteinases (MMP) during the bonding procedure. MMP inhibitors may be used to contain this process. Objective To evaluate the degree of conversion (DC%), dentin bond strength (µTBS) (immediate and after 1 year of storage in water), and nanoleakage of an experimental (EXP) and a commercial (SB) adhesive system, containing different concentrations of the MMP inhibitor GM1489: 0, 1 µM, 5 µM and 10 µM. Methodology DC% was evaluated by FT-IR spectroscopy. Dentin bond strength was evaluated by µTBS test. Half of beams were submitted to the µTBS test after 24 h and the other half, after storage for 1 year. From each tooth and storage time, 2 beams were reserved for nanoleakage testing. Data were analyzed using ANOVA and Tukey's test to compare means (α=0.05). Results All adhesive systems maintained the µTBS after 1 year of storage. Groups with higher concentrations of inhibitor (5 µM and 10 µM) showed higher µTBS values than groups without inhibitor or with 1 µM. The nanoleakage values of all groups showed no increase after 1 year of storage and values were similar for SB and EXP groups, in both storage periods. The inhibitor did not affect the DC% of the EXP groups, but the SB5 and SB10 groups showed higher DC% values than those of SB0 and SB1. Conclusions The incorporation of GM1489 in the adhesive systems had no detrimental effect on DC%. The concentrations of 5 µM GM1489 for SB and 5 µM or 10 µM for EXP provided higher µTBS than groups without GM1489, in the evaluation after 1 year of storage; whereas the concentration of inhibitor did not affect adhesive systems nanoleakage.


Assuntos
Cimentos Dentários/química , Dentina/química , Inibidores de Metaloproteinases de Matriz/química , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Análise de Variância , Colagem Dentária/métodos , Corrosão Dentária/métodos , Infiltração Dentária , Dentina/efeitos dos fármacos , Humanos , Teste de Materiais , Valores de Referência , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
5.
PLoS One ; 15(3): e0229595, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32119700

RESUMO

OBJECTIVES: To assess and compare the enamel surface quality after interproximal enamel reduction (IPR) was performed with different systems and to study the relation between acid penetration depth and enamel surface quality as well as the importance of remineralization. METHODS: Sixty-five extracted teeth were randomly allocated to five experimental groups: untreated control, manual with New Metal Strips, mechanical with oscillating segment (OS) discs, Safe-Tipped Bur Kit, and the Ortho-Strip, followed by 30 s of polishing with the Softflex system and the Compo-system after treating the tooth with OS discs. Mesial surfaces were demineralized for 24 h and distal surfaces were subjected to interchanging demineralization and remineralization cycles of 24 h each for 18 days. The analysis was carried out by profilometry, scanning electron microscopy, and polarization microscopy. RESULTS: After IPR and polishing, enamel roughness was reduced for all systems tested except for the Essix Safe-Tipped Bur Kit. Subsequent demineralization increased enamel roughness in all groups except controls beyond the original level prior to IPR except for IPR with New Metal Strips or Ortho-Strips and subsequent polishing. Cyclic demineralization and remineralization for 18 days yielded a reduction in acid penetration depth and an increase in surface smoothness, which correlated with each other only for controls and treatment with New Metal Strips or Ortho-Strips. CONCLUSIONS: Manual IPR, using New Metal Strips and, even more, the oscillating IPR system Ortho-Strips, yielded smoother interproximal enamel surfaces and less acid penetration depth than the IPR systems with OS discs and the Safe-Tipped Bur Kit after polishing and 18 days of cyclic demineralization and remineralization. Irrespective of the IPR procedure, proper remineralization of IPR-treated surfaces is advisable to reduce caries susceptibility.


Assuntos
Esmalte Dentário/fisiologia , Corrosão Dentária/métodos , Humanos , Microscopia Eletrônica de Varredura , Microscopia de Polarização , Propriedades de Superfície , Dente/fisiologia
6.
Niger J Clin Pract ; 23(1): 110-115, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31929216

RESUMO

OBJECTIVE: The aim of this study was to compare to effect of phototherapy and surface flattening after immediately bleaching on the shear bond strength to bleached enamel. METHODS: Ninety-six human upper incisors were divided into 4 groups (n = 24). Group NB: no bleached, group P: phototherapy with YSGG laser, group F: 0.5 mm surface flattening, group PF: 0.5 mm surface flattening and phototherapy with Er;Cr:YSGG laser. Then, each group was assigned to 2 subgroups according to adhesive mode (n = 12) as; subgroup S (self-etching mode), subgroup T (total-etching mode) which are universal adhesives. All surface conditionings and restorations were performed with composite resin materials immediately after bleaching. Shear bond strength test was performed by using universal testing machine. The surfaces were also evaluated with SEM. The data were statistically analyzed with one-way ANOVA post-hoc Tukey tests. RESULTS: The lowest SBS values were achieved in FS (13.72 ± 2.29) while the highest ones in PT (28.01 ± 6.81). However, the differences were not significant (P > 0.05). All surface conditioning methods provided SBS values similar to the control (P > 0.05). All subgroups of self-etching mode were significantly lower than their total-etching counterparts (P < 0.05). CONCLUSIONS: The present study showed that surface removal and phototherapy have a potential clinical application for eliminate to undesirable effect of bleaching treatment. Surface conditioning with either flattening and/or phototherapy may provide clinicians to restore bleached teeth at the same visit with bleaching and reduce chair-time.


Assuntos
Adesivos/farmacologia , Colagem Dentária/métodos , Esmalte Dentário/efeitos dos fármacos , Corrosão Dentária/métodos , Lasers de Estado Sólido/uso terapêutico , Fototerapia , Resistência ao Cisalhamento , Clareamento Dental , Condicionamento Ácido do Dente/métodos , Resinas Compostas/química , Materiais Dentários/química , Humanos , Teste de Materiais , Clareamento Dental/métodos
7.
J. appl. oral sci ; 28: e20190499, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1101251

RESUMO

Abstract Enzymatic degradation of the hybrid layer can be accelerated by the activation of dentin metalloproteinases (MMP) during the bonding procedure. MMP inhibitors may be used to contain this process. Objective To evaluate the degree of conversion (DC%), dentin bond strength (µTBS) (immediate and after 1 year of storage in water), and nanoleakage of an experimental (EXP) and a commercial (SB) adhesive system, containing different concentrations of the MMP inhibitor GM1489: 0, 1 µM, 5 µM and 10 µM. Methodology DC% was evaluated by FT-IR spectroscopy. Dentin bond strength was evaluated by µTBS test. Half of beams were submitted to the µTBS test after 24 h and the other half, after storage for 1 year. From each tooth and storage time, 2 beams were reserved for nanoleakage testing. Data were analyzed using ANOVA and Tukey's test to compare means (α=0.05). Results All adhesive systems maintained the µTBS after 1 year of storage. Groups with higher concentrations of inhibitor (5 µM and 10 µM) showed higher µTBS values than groups without inhibitor or with 1 µM. The nanoleakage values of all groups showed no increase after 1 year of storage and values were similar for SB and EXP groups, in both storage periods. The inhibitor did not affect the DC% of the EXP groups, but the SB5 and SB10 groups showed higher DC% values than those of SB0 and SB1. Conclusions The incorporation of GM1489 in the adhesive systems had no detrimental effect on DC%. The concentrations of 5 µM GM1489 for SB and 5 µM or 10 µM for EXP provided higher μTBS than groups without GM1489, in the evaluation after 1 year of storage; whereas the concentration of inhibitor did not affect adhesive systems nanoleakage.


Assuntos
Humanos , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Cimentos Dentários/química , Dentina/química , Inibidores de Metaloproteinases de Matriz/química , Metacrilatos/química , Valores de Referência , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Colagem Dentária/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Infiltração Dentária , Dentina/efeitos dos fármacos , Corrosão Dentária/métodos
8.
Niger J Clin Pract ; 22(12): 1758-1764, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31793485

RESUMO

AIM: The aim of this in vitro study was to compare the effects of the application of three different cavity disinfecting agents to dentin on the micro-shear bond strength (µ-SBS) of one self-etch and two universal adhesive systems. MATERIALS AND METHODS: In total, 120 caries-free human permanent molar teeth were used in this study. Mid-coronal dentin surfaces were revealed by cutting occlusal enamel and a standard smear layer was obtained by using 600-800-1200 grid silicon carbide abrasive papers. Specimens were randomly assigned to four groups according to the disinfectant used: Group 1: Control (no disinfectant); Group 2: 2% chlorhexidine based (Consepsis); Group 3: 10 ppm ozonated water (TeknO3zone); Group 4: 5% boric acid (Handmade). Each group was divided into three subgroups according to the type of adhesive (Clearfil SE Bond, OptiBond XTR, and Tokuyama Universal). Specimens were bonded using either Clearfil SE Bond, OptiBond XTR or Tokuyama Universal, which were employed according to the manufacturer's instructions. Resin composite microcylinders were bonded using Tygon® tubes for µ-SBS testing. After specimens were stored for 24 h, at 37°C in distilled water, µ-SBS test was measured with a universal test machine (LF Plus, Lloyd, Instrument). µ-SBS results were analyzed by one-way analysis of variance (ANOVA) and Tukey's tests. RESULTS: When the mean microshear bond strength values of the control group were compared, the difference between the subgroups was not significant (P < 0.05). When the mean microshear bond strength values of the chx, ozonated water, and boric acid were compared, the difference between Clearfil SE Bond and Tokuyama Universal was significant (P < 0.05) and the difference between the other groups was not significant (P > 0.05). CONCLUSION: Ozonated water and boric acid may be as an alternative to other materials used as cavity disinfectants.


Assuntos
Ácidos Bóricos , Colagem Dentária/métodos , Cimentos Dentários , Desinfetantes de Equipamento Odontológico/farmacologia , Adesivos Dentinários , Dentina/efeitos dos fármacos , Água , Clorexidina , Resinas Compostas/química , Esmalte Dentário , Corrosão Dentária/métodos , Humanos , Cimentos de Resina/uso terapêutico , Camada de Esfregaço
9.
Niger J Clin Pract ; 22(10): 1441-1447, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31607737

RESUMO

BACKGROUND: There was no enough data about the appropriate surface cleaning of core composite material after temporary cementation. AIM: To evaluate the effects of surface cleaning techniques on initial shear bond strength (SBS) between core composite material and resin nanoceramic crown materials after temporary cementation. MATERIAL AND METHODS: Cubic specimens were prepared from prosthetic materials, including Lava Ultimate. Cylinder-shaped composites were cemented to glass slides with eugenol-free temporary cement, resulting in a total of 44 cylinders (n = 11). The surfaces of composite cylinders were then cleaned with an Er, Cr:YSGG laser, 37% orthophosphoric acid, yellow tape diamond bur, or dental explorer. Cleaned cylinders were bonded to cubic specimens with resin cement. Initial SBS tests were performed with a universal testing machine at 0.5 mm/min crosshead speed. One-way ANOVA and post hoc Tukey tests were used to analyze the obtained data (P =0.05). RESULTS: Initial SBS values were significantly affected by the different surface cleaning methods (P <.05). The highest SBS value was obtained with the laser group (SBS = 17.14), while the lowest was obtained with dental explorer group (SBS = 5.95). There was no significant difference between the diamond bur group and the laser group (P =0.982). CONCLUSIONS: Laser irradiation or yellow tape diamond bur cleaning of the core composite surface could be recommended to strengthen bond strength between the resin luting cement and the core composite. Before adhesive or conventional cementation of prosthetic restoration, the core composite surface should be cleaned.


Assuntos
Colagem Dentária/métodos , Cimentos Dentários/química , Corrosão Dentária/métodos , Adesivos Dentinários/química , Vidro/química , Lasers de Estado Sólido/uso terapêutico , Cimentos de Resina/química , Cimentação , Resinas Compostas/química , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Resistência ao Cisalhamento , Propriedades de Superfície
10.
Int Orthod ; 17(4): 744-757, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31543426

RESUMO

BACKGROUND DATA: Enamel microcrack formation has a high incidence after mechanical debonding of ceramic brackets. This may be due to high delivered shear bond strength values when enamel is priorly etched by phosphoric acid. It is still not well elucidated in the literature if laser etching affects enamel the same way. The aim of the research was to analyze different Er,Cr:YSGG and Er:YAG laser etching settings as an alternative to phosphoric acid, in an attempt to prevent enamel microcrack formation during laser etching and mechanical debonding, while reducing the shear bond strength to the minimal clinical acceptable value. MATERIALS AND METHODS: One hundred and thirty-three teeth were randomly divided into 7 experimental groups according to their etching modalities. Settings used for enamel etching were in Er,Cr:YSGG groups: Er,Cr:YSGG (1.5Watt, W/20Hertz, Hz); Er,Cr:YSGG (1.5W/15Hz) and Er,Cr:YSGG (2W/20Hz) and settings used for enamel etching in Er:YAG groups were: Er:YAG (60 millijoules, mJ), Er:YAG (80mJ) and Er:YAG (100mJ). Group C etched with 37% phosphoric acid served as control. Microscopic analysis was performed to assess presence of enamel microcracks. Shear bond strength was evaluated after thermocycling using Weibull survival analysis. RESULTS: All groups showed a reduction in additional microcracks after debonding when compared to control, but only group Er:YAG (60mJ) exhibited a statistically significant difference. Groups Er:YAG (80mJ), control and Er:YAG (100mJ) showed respectively the highest probability of survival at various stress levels followed by groups Er:YAG (60mJ); Er,Cr:YSGG (1.5W/15Hz); Er,Cr:YSGG (2W/20Hz) and Er,Cr:YSGG (1.5W/20Hz) that presented a relatively considerable risk of failure, even at low stress levels. CONCLUSIONS: When considering reduction of enamel microcrack formation and clinical acceptable shear bond strength, none of the groups succeeded both. Etching by Er:YAG (60mJ) and Er,Cr:YSGG (1.5W/15Hz), showed the least overall microcrack incidence between groups, but Er:YAG (60mJ) displayed significant reduction compared to phosphoric acid. However, etching by Er:YAG (80mJ) had the most predictable results in term of shear bond strength.


Assuntos
Colagem Dentária/métodos , Descolagem Dentária/métodos , Esmalte Dentário , Corrosão Dentária/métodos , Braquetes Ortodônticos , Resistência ao Cisalhamento , Fraturas dos Dentes/patologia , Condicionamento Ácido do Dente , Cerâmica , Esmalte Dentário/ultraestrutura , Análise do Estresse Dentário , Humanos , Lasers de Estado Sólido , Teste de Materiais , Ácidos Fosfóricos , Análise de Regressão , Propriedades de Superfície
11.
BMC Oral Health ; 19(1): 178, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31387557

RESUMO

BACKGROUND: The aim of this study was to evaluate the effect of universal adhesives (UA) and silane on the microtensile bond strength (µTBS) of resin cement to a hybrid ceramic Vita Enamic (VE). METHODS: VE specimens were acid etched using hydrofluoric acid (HF) and were assigned to three groups (n = 10) based on the applied bonding technique. In group 1 (S), a silane-based primer was used as a surface treatment prior to the application of a resin cement (Variolink Esthetic DC). In group 2, a silane-containing UA, Clearfil Universal Bond (CUB) was used for the surface treatment, and in group 3, A silane-free UA, Tetric N-Bond Universal (TNU) was used for surface treatment. Resin cement build-ups were prepared. The bonded specimens were sectioned into resin-ceramic beams. Half of the beams of each group were stored for 24 h at 37 °C and the other half were subjected to a thermo-cycling aging. The microtensile bond strength (µTBS) was measured at a crosshead speed of 0.5 mm/min. Failure modes were assessed accordingly. Data were analyzed using a) two-way analysis of variance ANOVA followed by one-way ANOVA and Tukey tests between groups and b) independent t-test to detect differences (α = 0.05) for each group. The surface topographies of the ceramic surface were evaluated using scanning electron microscopy. RESULTS: The results showed that silane-based primer (S) application resulted in significantly higher (p < 0.05) µTBS values after 24 h and after thermocycling compared to both silane-containing UA (CUB) and silane-free UA (TNU). The µTBS values of all groups were significantly reduced after thermocycling. No statistically significant difference was observed between the µTBS of CUB and TNU after 24 h. However, TNU showed significantly higher µTBS after thermocycling. Different failure modes were observed, and adhesive failure was the most common in all groups. Marked surface topographic changes were observed following HF etching. CONCLUSION: It is concluded that, the UAs tested cannot be recommended as substitutes to the silanization of Hybrid ceramic.


Assuntos
Cerâmica/química , Colagem Dentária , Cimentos de Resina/química , Condicionamento Ácido do Dente , Cimentos Dentários , Corrosão Dentária/métodos , Porcelana Dentária/química , Análise do Estresse Dentário , Estética Dentária , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Resistência à Tração
12.
Photobiomodul Photomed Laser Surg ; 37(8): 465-472, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31390314

RESUMO

Objective: The purpose of this study was to evaluate the effects of Er,Cr:YSGG laser irradiation with different energy powers versus sandblasting for enhancing the tensile bond strength (TBS) between titanium implant abutments (IAs) and resin cements. Background data: Clinical decementation of prosthetic restorations often occurs, particularly on short IAs. Increasing the bonding area on the IA surface can enhance the function and longevity of the superstructure. Materials and methods: Fifty dental IAs were used in solid form and randomly assigned to five groups (n = 10 each) for the following different pretreatments: control group was left untreated, a laser operating at 2.78 µm wavelength with different energy powers (1, 2, and 3 W) was used for three laser groups, and 50 µm alumina particles were applied to the abutment surface for the sandblasting group. Fifty metal substructures that had an occlusal metal O-ring were cast and cemented to all abutments using dual-cure resin cement. Test specimens were then subjected to thermal cycling. TBS tests were performed with a universal testing machine. The specimens' surface topography and roughness were evaluated with scanning electron microscope, and energy dispersive spectroscopy (EDS) was used to measure the elemental profiles of each specimen. Data were analyzed using a one-way analysis of variance/Kruskal-Wallis test at a significance level of p < 0.05. Results: Surface treatments affected the surface roughness and TBS of the IA. The sandblasting group showed the highest bond strength values (510.77 ± 60.86 N) and followed by the 2 W group (279.07 ± 37.9 N). In EDS analysis, no elemental components other than titanium and oxygen were observed, except for in the sandblasting group. Conclusions: Sandblasting and 2 W laser treatment increased the surface roughness of the IA, which could contribute to the increased interfacial bond strength between the IA and resin cement.


Assuntos
Dente Suporte , Colagem Dentária/métodos , Corrosão Dentária/métodos , Lasers de Estado Sólido , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Cimentos de Resina/química , Espectrometria por Raios X , Propriedades de Superfície , Resistência à Tração , Titânio/química
13.
Microsc Res Tech ; 82(10): 1668-1680, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31259458

RESUMO

The study aimed at finding an optimal combination of acid concentration and etching time when nitric acid is used as etchant for the study of the finer details of human dental enamel structure. Four hundred 2-3-mm-thick segments of facio-lingually sectioned human third molar crowns were assigned to 20 groups with 20 specimens in each group, each group differing with respect to acid concentration (0.1, 1, 2.5, and 5%) and etching time (15, 30, 45, 90, and 180 s). After etching and preparation, specimens were observed in the scanning electron microscope (SEM). Surface roughness/topography increased with increasing acid concentration and increasing etching time, but not in a linear fashion; generally, prisms tended to go from flat-surfaced to cone-shaped and prism sheaths from fissure-like to wedge-shaped. Intragroup variations and intergroup similarities were considerable. The two major enamel factors determining the etch effect are crystal orientation and prism sheath properties. Other factors, such as distribution of porosities and crystal quality, also contribute probably. Slight to moderate topography is best for observing the finer enamel structure, for example, etching with concentrations in the range 0.1-1% and with etching times in the range 15-90 s, the stronger the acid, the shorter the time. The depth effect of nitric acid is judged to be relatively small. Considerable variations in expression of prism cross-striations were observed. SEM observations of acid-etched enamel in carefully selected planes are a powerful method for the study of enamel structure, bearing in mind the artifactual aspects of the observed surface.


Assuntos
Ácidos/metabolismo , Esmalte Dentário/ultraestrutura , Corrosão Dentária/métodos , Humanos , Microscopia Eletrônica de Varredura , Dente Molar/ultraestrutura , Propriedades de Superfície , Fatores de Tempo
14.
Photobiomodul Photomed Laser Surg ; 37(7): 442-450, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31265379

RESUMO

Objective: This study compared the effects of different surface treatments on the surface roughness (Ra), and shear bond strength (SBS) of resin cement to yttria-stabilized tetragonal zirconia (Y-TZP) ceramic and nickel-chromium (Ni-Cr) base metal alloy, respectively. Materials and methods: Thirty disk-shaped specimens (3 mm height and 10 mm diameter) of each material (Y-TZP and Ni-Cr) were prepared. Both zirconia and metal specimens were randomly assigned to three equal groups, according to the surface treatments (n = 10): sandblasting, sandblasting + Er:YAG laser, and sandblasting + Nd:YAG laser. Resin cement cylinders (4 mm diameter and 3 mm thickness) were placed on each specimen. The SBS tests were performed at a 1 mm per minute crosshead speed through a knife-edge rod after 5000 thermal cycles. The Ra (µm) of the specimens was measured using a profilometer and evaluated topographically by atomic force microscopy and scanning electron microscopy. Analysis of variance, followed by Tukey's honestly significant difference, in addition to the Kruskal-Wallis test, followed by the Mann-Whitney U test, were used for statistical analysis (α = 0.05). Results: Combined sandblasting and laser treatment of the metal groups led to statistically higher Ra values than sandblasting alone (p < 0.05). For Y-TZP, there were no significant differences between the Ra values of the subgroups (p > 0.05). The SBS of the sandblasted metal group was significantly higher than the other two laser-irradiated groups, whereas the SBS of sandblasted zirconia was only significantly higher than the Nd:YAG laser-irradiated group (p < 0.05). Conclusions: Combined laser and sandblasting surface treatments resulted in rougher surfaces than sandblasting alone, especially for the metal specimens. Sandblasting, alone, improved the SBS of resin cement in both metal and zirconia, compared with the laser and sandblasting treatments, combined.


Assuntos
Ligas de Cromo/química , Ligas Dentárias/química , Colagem Dentária/métodos , Corrosão Dentária/métodos , Porcelana Dentária/química , Lasers de Estado Sólido , Cimentos de Resina/química , Ítrio/química , Zircônio/química , Teste de Materiais , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento/efeitos da radiação , Propriedades de Superfície
15.
Photobiomodul Photomed Laser Surg ; 37(7): 434-441, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31265377

RESUMO

Objective: The purpose of this study is to investigate the effect of various presintering and sintered surface treatments and thermocycling on the bond strength between zirconia and veneer ceramics. Background data: Bond stability between zirconia and veneer ceramic is a major concern, and only limited evidence about its longevity is currently available. Moreover, no study has yet evaluated the influence of thermocycling on the bond strength of veneer ceramic to zirconia after Er,Cr:YSGG laser irradiation at different pulse durations and sandblasting. Materials and methods: In this study, 220 nonsintered zirconia specimens were prepared with CAD/CAM and randomly divided into 2 groups; half of the specimens in each group were stored in water for 1 week, and the other half were thermocycled (5000 cycles) between baths of 5°C and 55°C. Specimens were then divided into five subgroups based on the following surface treatments: control (untreated surface), sandblasting (120 µm Al2O3), and Er,Cr: YSGG laser irradiations (3 W-8 Hz, 3 W-15 Hz, and 3 W-20 Hz, MGG 6 laser tip, for 20 sec, distance of 10 mm, water/airflow of 55% and 65%). Morphological assessment was done using atomic force microscopy and scanning electron microscopy, and phase transformation was assessed by X-ray diffractometry. All specimens were then veneered with veneering ceramic, and bond strength test using a universal testing device at a 1 mm/min crosshead speed. Data were evaluated by Kruskal-Wallis variance analysis and the Mann-Whitney U test. Results: There was no significant difference in the bonding strength values among the (p > 0.05). Thermocycling reduced the bond strength, but it was not significant (p > 0.05), except for the presintering 20 Hz group (p < 0.02). Conclusions: Application of thermocycling to sintered zirconia specimens may be detrimental to the shear bond strength of zirconia ceramics. Treating the zirconia surface after sintering is not recommended, due to the decrease in bond strength.


Assuntos
Cerâmica/química , Colagem Dentária/métodos , Corrosão Dentária/métodos , Materiais Dentários/química , Lasers de Estado Sólido , Resistência ao Cisalhamento/efeitos da radiação , Zircônio/química , Desenho Assistido por Computador , Facetas Dentárias , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
16.
Photobiomodul Photomed Laser Surg ; 37(7): 428-433, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31265378

RESUMO

Objective: Evaluate the bond strength of repairs made on composite resin following the treatment of the surface of the flaw with different bonding agents and/or CO2 laser. Background: The influence of CO2 laser and its interaction with other bonding agents on the surface of the flaw is not yet known. In this study, CO2 laser was chosen to treat the surface of the flaw due to its capacity to promote irregularities on the surface that enhance mechanical micro-retention. Methods: A block was created with Vitra APS nanohybrid composite resin (color: A3; FGM, Joinville, Brazil) measuring 5 mm in width, length, and depth (volume: 125 mm3). The surface of the flaw was treated before the repair with an adhesive, silane bonding agent, and/or CO2 laser. Six specimens were created in composite resin for each group (total: n = 36): G1: resin+resin; G2: adhesive+resin; G3: laser+adhesive; G4: laser+silane+adhesive; G5: silane+adhesive; G6: laser+silane. After the repair, the surfaces of the fracture of all specimens, which were submitted to the microtraction test, were analyzed under an optical microscope. Bond strength values obtained according to the type of surface treatment were tabulated and submitted to the Kruskal-Wallis test. Dunn's test was used to compare means. Results: G3 and G4 had significantly higher bond strength values compared to all other groups tested. Adhesive fractures predominated in all groups. However, G3 and G4 had a higher percentage of cohesive fractures compared to the other groups. Conclusions: The application of CO2 laser as a surface treatment led to greater bond strength of composite resin repairs in comparison with the groups that only received treatment with a burr and silanization. The groups submitted to CO2 laser also had a significantly lower number of adhesive failures when submitted to the microtraction test.


Assuntos
Resinas Compostas/química , Colagem Dentária , Esmalte Dentário/efeitos da radiação , Corrosão Dentária/métodos , Materiais Dentários/química , Lasers de Gás , Dióxido de Carbono , Análise do Estresse Dentário , Adesivos Dentinários/química , Teste de Materiais , Resistência ao Cisalhamento/efeitos da radiação , Estresse Mecânico , Propriedades de Superfície
17.
Lasers Surg Med ; 51(9): 797-807, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31168853

RESUMO

BACKGROUND AND OBJECTIVES: The employability of the non-invasive femtosecond laser ablation technique for dental treatment has been severely limited by its low ablation rate despite the advantage of minimal tissue damage. The study explores a means of improving the femtosecond laser ablation rate and efficiency by physiochemical surface modification. MATERIALS AND METHODS: Surface modification of dental hard tissues has been carried out by food graded orthophosphoric acid and Carie care gel pretreatment. The laser ablation characteristics were studied by using a Ti:Sapphire laser (10 kHz, 10 mm/s, 100 fs, 800 nm) to ascertain the influence of pretreatment. Surface morphology and chemical composition were obtained by using an optical profiler, SEM and EDAX. RESULTS: The ablation threshold fluence decreased by almost one-third whereas the ablation rate and ablation efficiency nearly tripled upon pretreatment. The microstructural and compositional analysis clearly reveals that surface modification and demineralization reduce the threshold fluence and increase the ablation rate by effective utilization of the laser beam energy. The pretreatment effect is more pronounced in orthophosphoric acid as compared with Carie care gel. CONCLUSIONS: Physiochemical surface modification can be an efficient method to improve the laser ablation rate and ablation efficiency. Compositional analysis can be an elegant tool for pre-surgery determination of laser ablation characteristics. CLINICAL SIGNIFICANCES: Pretreatment surface modification can be an effective way to overcome the limitation of the femtosecond laser for tooth preparation in the clinical setting by strongly enhancing the ablation rate. An enhanced ablation rate along with de nova prediction of ablation characteristics will enable the clinician to perform dental surgery in real time with minimal tissue damage. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Assuntos
Corrosão Dentária/métodos , Terapia a Laser , Dente/efeitos da radiação , Adolescente , Adulto , Humanos , Terapia a Laser/métodos , Microscopia Eletrônica , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Dente/anatomia & histologia , Adulto Jovem
18.
Photobiomodul Photomed Laser Surg ; 37(8): 483-488, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31081712

RESUMO

Objective: The aim of this study was to assess the effect of Er;Cr:YSGG laser parameters (power and frequency) on the bond strength and color stability of lithium disilicate (LD) ceramics. Materials and methods: One hundred ten specimens of LD ceramic were fabricated following heat pressed technique. Fifty disks were randomly distributed into five groups according to types of surface treatment [hydrofluoric (HF) acid, L1S L2S, L1D, and L2D]. For all laser-treated groups, bond preparation settings were used with a gold hand piece using a MZ10 tip (Er;Cr:YSGG, water lase I plus; Biolase). After surface treatment, adhesive bond was applied, and after photopolymerization, a composite buildup was performed. To evaluate shear bond strength, a controlled force was applied until failure using a universal testing machine. Color stability was assessed for six groups (HF, L1S L2S, L1D, L2D, and control) of LD ceramic (shade A1, LT translucency) through the CIE L*a*b* system. Three specimens from each of the six groups were selected randomly for assessment of surface topography using scanning electron microscopy. Means and standard deviations were compared using analysis of variance and Tukey's post hoc test (p < 0.05). Results: The maximum and minimum mean bond strength were shown by the L2D group 19.95 ± 1.014 and L1S group specimens 14.68 ± 0.863, respectively. Highest mean ΔE was found in L2S group 8.17 ± 2.10 and the lowest mean ΔE was found in control group (no treatment) 0.11 ± 0.05. Conclusions: LD specimens lased (Er;Cr:YSGG) with 3.75 W power and 15 Hz frequency for 4 min showed bond strength comparable with HF acid samples, and color changes within acceptable range (ΔE 1.17). Laser treatment (Er;Cr:YSGG) at 3.75 W power and 15 Hz frequency for 4 min of LD ceramics appears to be clinically efficient, showing acceptable bond strength and color stability.


Assuntos
Cerâmica/química , Colagem Dentária/métodos , Corrosão Dentária/métodos , Porcelana Dentária/química , Lasers de Estado Sólido , Cor , Análise do Estresse Dentário , Ácido Fluorídrico , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Propriedades de Superfície
19.
Photobiomodul Photomed Laser Surg ; 37(8): 473-482, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31081715

RESUMO

Objective and background: Different surface treatments have been tested in composite repair studies. However, there is still no consensus on the most effective repair protocol. The aim of this study is to measure the roughness values of eight different surface treatments for the repair procedure, to examine the effect of each surface treatment and three different composites on the repair bond strength with and without silane, and to evaluate whether there is a correlation between bond strength and roughness. Methods: The blocks were prepared with Filtek Z550 (3M ESPE) for the roughness measurements and divided into eight groups according to surface treatments. The roughness values of the surface treatments were measured by a 3D scanning contact profilometer (Nanomap LS). For the shear test, further samples were prepared, aged, and divided into three subgroups for the repair procedure with Filtek Z550 (3M ESPE), Vertise Flow (Kerr, USA), and G-aenial Flo (GC, Japan) after the surface treatments. Then, the shear test was performed. The Kruskal-Wallis and Spearman's Correlation tests were used for statistical evaluation of the data. Results: Significant differences were found between surface treatments and composite resins in terms of bond strength (p < 0.05). There is no correlation between the roughness and bond strength values. Conclusions: In bond strength, surface topography is more important than the numerical value of roughness. In the repair of composite restorations, methods that are already in clinical practice and more practical can be used instead of methods that require additional costs and devices.


Assuntos
Resinas Compostas/química , Colagem Dentária/métodos , Corrosão Dentária/métodos , Lasers de Estado Sólido , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento/efeitos da radiação , Silanos/química , Propriedades de Superfície
20.
Clin Oral Investig ; 23(12): 4345-4353, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30953165

RESUMO

OBJECTIVES: To evaluate the critical bond strength (σ) of ceramic and metal brackets to a lithium disilicate-based glass-ceramic. MATERIALS AND METHODS: Two hundred and forty ceramic specimens (IPS e-max CAD) were randomly distributed in 12 experimental groups (n = 20). Two ceramic brackets (monocrystalline, BCm; and polycrystalline, BCp) and a metal bracket (BM) were bonded to glass-ceramic specimens after one of the following surface treatments: HF-hydrofluoric acid applied for 60 s; S-silane applied for 3 min; HFS-HF followed by S; and MDP-application of an adhesive containing a phosphate monomer (MDP). All brackets were bonded to the treated glass-ceramic using a resin cement, stored in 37 °C water for 48 h before shear bond strength testing. Optical (OM) and scanning electron (SEM) microscopies were used for fractographic analysis. Data was statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls (α = 0.05). RESULTS: BCm bonded to glass-ceramic treated with either HFS or HF showed the highest median σ values, respectively, 10.5 MPa and 8.5 MPa. In contrast, the BCp bonded to glass-ceramic treated with MDP showed the lowest median σ value (0.8 MPa), which was not statistically different from other MDP-treated groups. CONCLUSIONS: The failure mode was governed by the glass-ceramic surface treatment, not by the bracket type. Quantitative (σ values) and qualitative (fracture mode) data suggested a minimum of 5 MPa for brackets bonded to glass-ceramic, which is the lower critical limit bond strength for a comprehensive orthodontic treatment. CLINICAL RELEVANCE: Bonding brackets to glass-ceramic requires micromechanical retention.


Assuntos
Cerâmica/química , Colagem Dentária , Corrosão Dentária/métodos , Teste de Materiais/métodos , Braquetes Ortodônticos , Análise do Estresse Dentário , Humanos , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...